Design of Fluid & Thermal Elements (EMAE 355) • Fall 2026

sCO₂ Turbine Bearing Cooling & 350-Bar H₂ Fuel-Cell UAV

Two thermofluid design projects completed with Team 14 in EMAE 355 (advised by Prof. Steve Hostler): (1) a self-contained supercritical CO₂ bearing cooling loop for a 40,000 RPM turbine operating across −20°C to 50°C ambient conditions, and (2) a 350-bar compressed-hydrogen fuel-cell UAV propulsion system and mobile ground refueling station.

CoolProp Real-Fluid EOS sCO₂ P-h State Tracking Counterflow Heat Exchanger (LMTD) Joule-Thomson Throttling Flight Mechanics ODEs
sCO2 Turbine Dual-Tap Bearing Cooling Loop Schematic

Dual-tap sCO₂ bleed architecture routing cold pump discharge (State 2) and warm recuperator outlet (State 3) through a counterflow HX to cool the 40,000 RPM bearings.

Project 1 • Closed-Loop sCO₂ Thermal Management

40,000 RPM sCO₂ Turbine Bearing Cooling System

In a closed-loop supercritical CO₂ (sCO₂) power cycle spinning at 40,000 RPM (with a 450°C turbine inlet temperature), the high fluid density near the critical point (31°C, 7.38 MPa) creates significant frictional windage heating inside the two radial journal bearings and thrust bearing (~2.3 kW at ρ = 140 kg/m³ across a 5 mm² bearing orifice).

Our goal was to bleed CO₂ directly from existing cycle lines to keep the bearing outlet temperature strictly below 100°C (373.15 K) without adding an external secondary coolant loop, while guaranteeing single-phase flow inside the bearings (no liquid condensation or solid dry-ice formation after throttling) across 8 steady-state ambient temperatures (−20°C to 50°C) plus startup.

Dual-Tap Bleed Architecture & Hardware

To adapt across both subcritical cold days and supercritical hot days, we designed a two-line bleed loop using two actuated Mark 708MV micro-flow control valves and a compact concentric-tube aluminum counterflow heat exchanger:

  • Cold Coolant Line (State 2 → 2' → 2'' → 6'): Taps high-pressure, low-temperature CO₂ after the main pump (State 2: 12°C–85°C, 11.0–20.7 MPa) via 1/4" aluminum tubing, throttles it through Valve 2 (Cv = 0.006–0.037) down to State 2' just above turbine exhaust pressure (P1 = P6), passes it through the heat exchanger to State 2'', cools the bearings, and returns to State 6 ahead of the condenser.
  • Hot Pre-Heating Bypass (State 3 → HX → Return): Taps warm CO₂ downstream of the recuperator (State 3: 78°C–200°C) via 1/2" aluminum tubing and Valve 3 (Cv = 0.000–0.011) to warm the throttled coolant whenever cold ambient conditions cause State 2' to drop inside the two-phase vapor dome.
sCO2 cycle schematic with dual-tap bearing cooling loop

Cycle schematic showing the State 2 coolant tap and State 3 hot bypass feeding the counterflow HX and bearing cavity.

Concentric-tube counterflow heat exchanger schematic

Concentric-tube counterflow heat exchanger layout routing cold throttled CO₂ (di) against warm State 3 bypass flow (do).

CoolProp Enthalpy Tracking, Choked Flow Check & HX Sizing

On this project, my primary responsibility covered the CoolProp enthalpy path tracking, the valve throttling and choked-flow calculations, and verifying the draft thermal analysis across all 9 operating cases:

  • Isenthalpic Throttling & Mach Check (State 2 → 2'): Modeled the control valve as an isenthalpic throttle (h2' = h2) across pressure drops of 4.8 to 13.8 MPa. Using nozzle velocity relations and CoolProp speed-of-sound lookups across all 9 states, I verified that the peak throat Mach number is M = 0.86 (at 40°C ambient), confirming the flow never chokes (M < 1).
  • Two-Phase Mitigation (State 2' → 2''): From −20°C to 20°C (and startup), P2' (3.9–6.2 MPa) sits below Pcrit (7.38 MPa), so throttling from State 2 lands directly inside the liquid-vapor dome (vapor quality x = 0.02–0.04). To prevent liquid droplets from eroding the 40,000 RPM bearings, the heat exchanger warms the stream to 5 K superheat above saturation before entering the bearing cavity. At 30°C–50°C ambient, P1 ≥ 7.4 MPa is already supercritical, so Valve 3 closes completely (Cv = 0) to save cycle power.
  • Heat Exchanger Conductance & Parasitic Power (State 2'' → 6'): Using the bearing energy balance ṁcoolant = Q̇gen / (h6' − h2'') to cap outlet temperature at T6' = 100°C, the 20°C ambient case set our maximum required heat exchanger conductance at UA = 0.134 kW/K. Across the entire envelope, the cooling loop draws at most 864 W of parasitic fluid power (Ẇfluid = V̇ΔP) with an estimated hardware BOM cost of $230.
Annotated CO2 Pressure-Enthalpy diagram showing States 2, 2', 2'', and 6'

Annotated CO₂ Pressure-Enthalpy (P-h) diagram for the 20°C design case showing isenthalpic valve throttling into the vapor dome (2 → 2' at 272 kJ/kg), isobaric HX heating to 5 K superheat (2' → 2'' at 421 kJ/kg), and single-phase heat absorption across the bearings (2'' → 6' at 533 kJ/kg).

Project 2 • Propulsion & Transient Blowdown

350-Bar Hydrogen Fuel-Cell UAV & Mobile Refueling Station

In our second EMAE 355 project, we designed a compressed-hydrogen PEM fuel-cell propulsion system and a containerized ground refueling station for a fixed-wing UAV cruising at 3,000 m altitude (35 kg base airframe, 230 kg max takeoff weight, 3.025 m² wing area, CL = 0.60, ηp = 90% propulsive efficiency).

Trade Studies & Component Integration
  • Hydrogen vs. Lithium-Ion Battery Baseline: Because hydrogen has a lower heating value of 120 MJ/kg compared to ~0.36 MJ/kg for lithium-ion batteries, a max-weight 195 kg battery pack only achieved 1,680 km in our baseline Breguet range check, whereas our hydrogen setup reached 5,512 km (34.4 hours endurance) after accounting for external tank drag.
  • 350-Bar Compressed Gas vs. Cryogenic Liquid H₂: We selected 350 bar (35 MPa) compressed gas in a Luxfer G-Stor Pro H2 Type III carbon-fiber cylinder (322 L volume, 7.8 kg H₂ capacity, 138 kg empty mass) over liquid H₂ (−253°C) to avoid cryogenic boil-off venting and active cooling weight.
  • Fuel Cell & Mass Budget: Paired the tank with an Intelligent Energy IE-SOAR 2.4 kW PEM fuel cell stack (4.8 kg) and integrated pressure regulator (stepping tank pressure down to 0.19 MPa / 1.9 bar), bringing initial takeoff mass to m0 = 185.6 kg and final empty mass to m1 = 177.8 kg.
Flight Mechanics ODEs & Transient Weight Decay

I led the flight mechanics derivation and transient fuel-consumption modeling at 3,000 m ISA conditions (Ta = −4.5°C, ρa = 0.909 kg/m³). Starting from steady level flight equilibrium (L = W, T = D), I derived the hydrogen-specific Breguet range formula and set up the coupled ordinary differential equation governing aircraft mass decay m(t) and required shaft power P(t) as fuel is burned:

dm/dt = −Pshaft / (ηfc · LHV) = −K · m(t)3/2  ⇒  m(t) = [ m0−1/2 + (K/2)t ]−2
Full Breguet Range & Transient Mass ODE Derivation

5-page step-by-step derivation of the hydrogen Breguet range equation, system constant K, trip time, and m(t) / P(t) functions.

View Derivation PDF
Real-Gas Tank Blowdown & Inverse Joule-Thomson Heating

I also modeled the emptying of the 0.322 m³ tank across 21 discrete steps from full (36.68 MPa) to depleted (0.332 MPa) at 298 K, treating the pressure regulator as an isenthalpic throttle (h2 = h1) stepping down to the 0.19 MPa fuel cell inlet pressure.

This analysis highlighted an important real-gas effect: because hydrogen has a negative Joule-Thomson coefficient at room temperature (above its ~200 K inversion temperature), throttling H₂ across a large pressure drop causes it to warm up rather than cool down. At the start of the flight (36.7 MPa tank pressure), the regulated gas enters the fuel cell at 312.5 K (39.4°C) and gradually cools toward 298.0 K (24.9°C) as the tank empties. Because 24.9°C–39.4°C stays naturally inside the IE-SOAR fuel cell's −5°C to 40°C operating window for the entire 34.4-hour flight, we proved that no onboard pre-heating heat exchanger was needed—saving weight and complexity on the aircraft.

Transient tank blowdown, Joule-Thomson regulator temperatures, and ODE flight range spreadsheet

21-step transient blowdown and flight performance workbook tracking tank state (State 1), post-regulator Joule-Thomson temperatures (State 2: 312.5 K → 298.0 K), and numerical vs. analytical ODE mass and power decay over 124,000 seconds.

Mobile Refueling Container & Emissions

For ground support, our team designed a mobile refueling station inside a standard shipping container where the UAV lands and rotates vertically into a rack fed by upright compressed-H₂ storage cylinders. After comparing six industrial hydrogen pathways, we selected grey hydrogen (steam methane reforming) for the station due to cost and availability, which corresponds to 101.4 kg of CO₂ per 7.8 kg refill (0.0184 kg CO₂/km across the 5,512 km range).

Project 1 Summary (sCO₂)

Course & Team EMAE 355 • Team 14 (Prof. Hostler)
Turbine Specs 40,000 RPM, 450°C Inlet, 5 mm² Bearing Orifice
Ambient Range −20°C to 50°C (8 States + Startup)
Thermal Target Single-Phase Only, Bearing Outlet < 100°C
Control Hardware 2× Mark 708MV Valves (Cv = 0.006–0.037)
Max Valve Mach M = 0.86 at 40°C (Unchoked Across All States)
Heat Exchanger Al Counterflow HX (Max UA = 0.134 kW/K, 5 K Superheat)
Parasitic Power 864 W Max Fluid Power • $230 BOM Cost

Project 2 Summary (H₂ UAV)

Cruise Ceiling 3,000 m ISA (−4.5°C, ρ = 0.909 kg/m³)
Mass Budget 185.6 kg Takeoff → 177.8 kg Empty (7.8 kg H₂)
Storage Tank Luxfer G-Stor Pro H2 Type III (350 bar, 322 L)
Fuel Cell Stack Intelligent Energy IE-SOAR 2.4 kW PEM (0.19 MPa Inlet)
J-T Temp Shift 39.4°C (Full) → 24.9°C (Empty) • No HX Needed
Cruise Range 5,512 km (34.4 Hours Endurance)
Carbon Footprint 101.4 kg CO₂ / Flight (0.0184 kg CO₂/km, Grey H₂)

Key Takeaways

  • Mapped real-fluid sCO₂ states on P-h diagrams using CoolProp to prevent two-phase condensation inside 40,000 RPM bearings across −20°C to 50°C.
  • Verified unchoked valve throttling (M ≤ 0.86) and sized a counterflow heat exchanger (UA = 0.134 kW/K) that shuts off automatically above 30°C ambient.
  • Coupled flight-mechanics weight-decay ODEs with real-gas hydrogen blowdown, showing that inverse Joule-Thomson warming keeps the fuel cell within its temperature limits without an onboard heat exchanger.